2019白菜网送彩金

Fuel gas heat transfer oil furnace

Organic heat carrier furnace is a new type of special boiler, also known as thermal oil furnace. It has low pressure and high temperature working characteristics, and its heating temperature can reach 340 ℃ in liquid phase or 400 ℃ in vapor phase. For those processes that require uniform and stable heating and do not allow direct flame heating, the heating temperature is between 150 ° C and 380 ° C ...

Order online

400-0394-288 / 13673427999
0

model
project

YY (Q) W-
120Y (Q)

YY (Q) W-
240 Y (Q)

YY (Q) W-
350 Y (Q)

YY (Q) W-
500Y (Q)

YY (Q) W-
700 Y (Q)

YY (Q) W-
1000Y (Q)

YY (Q) W-
1200Y (Q)

YY (Q) W-
1400 Y (Q)

YY (Q) W-
1800 Y (Q)

YY (Q) W-
2100Y (Q)

YY (Q) W-
2400Y (Q)

YY (Q) W-
3000Y (Q)

YY (Q) W-
3500 Y (Q)

YY (Q) W-
4700Y (Q)

YY (Q) W-
6000 Y (Q)

YY (Q) W-
7000 Y (Q)

YY (Q) W-
10000 Y (Q)

Rated thermal power

KW

120

240

350

500

700

1000

1200

1400

1800

2100

2400

3000

3500

4700

6000

7000

10000

design pressure

MPa

1.1

Outlet temperature of medium

≤350

Heating area

2 m 2

9.8

14.5

21.3

twenty four

40

50

64.6

78.5

87

94.5

106.2

163

205.2

254.3

325

410

520

Applicable fuel

Light oil / natural gas / city gas

Light oil / heavy oil / natural gas / city gas

fuel
Consumption

Light oil

Kg / h

12

25

37

52

69

100

120

140

180

210

244

300

350

470

580

680

970

natural gas

3 /h Nm 3 / h

15

30

44

63

83

120

145

170

220

260

296

365

425

570

700

810

1160

Gas supply
pressure

natural gas

mbar

30-100

50-150

50-200

100-300

device
Total electricity
power

Light oil

KW

4

8

10

10

18

26

26

26

46

46

46

66

78

98

115

115

132

Gas

KW

4

8

10

10

18

25

26

26

46

46

46

64

72

95

110

110

128

Furnace oil content

3 m 3

0.1

0.15

0.25

0.3

0.5

0.8

0.85

1.1

1.2

1.7

1.9

3.5

3.8

4.2

6.2

7

10.5

Boiler dimensions

mm

1600 ×
1020 ×
1520

1930 ×
1230 ×
1868

2100 ×
1390 ×
2055

2200 ×
1390 ×
2055

3240 ×
1470 ×
2260

3300 ×
1670 ×
2486

3830 ×
1770 ×
2587

4145 ×
1900 ×
2786

4600 ×
2000 ×
3045

5020 ×
2050 ×
3080

5080 ×
2200 ×
3180

5983 ×
2420 ×
3404

6555 ×
2470 ×
3634

7285 ×
2570 ×
3760

7800 ×
3050 ×
3800

8200 ×
3050 ×
3800

10000 ×
3500 ×
4000

Boiler transport weight

T

1.5

2

2.58

3

3.7

5

5.8

6.7

7.8

8.8

9.8

15.5

17.8

21.5

25

27.5

32

imported oil

DN

45

65

80

100

125

150

200

250

300

Oil outlet

DN

45

65

80

100

125

150

200

250

300

Expansion tank

3 m 3

0.5

1.5

2

2.5

3

5

6

Oil storage tank

3 m 3

1

2.5

4

5

8

10

15

Chimney diameter φ

mm

200

280

350

400

500

600

700

CopyRight 2014-2016 swallabox.com, Inc. all Rights Reserved. Copyright: Henan Taiguo Boiler Manufacturing Co., Ltd. Tel: 0394-6778666 Zip code: 461423 E-mail: 1741148182@qq.com
Copyright statement: All text and pictures on this website are protected by the copyright of Henan Taiguo Boiler Manufacturing Co., Ltd., and may not be used or reproduced without permission, or they will be held liable. Excerpt. ICP800051890
online service

Scan code to communicate with me